{"id":1571,"date":"2015-11-06T15:24:37","date_gmt":"2015-11-06T15:24:37","guid":{"rendered":"https:\/\/lir.uc3m.es\/innpacto-remote-traffic-pollution-detection\/"},"modified":"2023-06-07T13:51:51","modified_gmt":"2023-06-07T13:51:51","slug":"innpacto-remote-traffic-pollution-detection","status":"publish","type":"post","link":"https:\/\/lir.uc3m.es\/en\/innpacto-remote-traffic-pollution-detection\/","title":{"rendered":"INNPACTO: Remote Traffic Pollution Detection"},"content":{"rendered":"\n<p><strong>INNPACTO: Multi-Lane System for the Detection of Emissions from Circulating Traffic<\/strong><\/p>\n\n\n\n<p>In the frame of this project, <strong>LIR Infrared LAB-UC3M<\/strong> has applied its expertise in gas detection in the <strong>development of a prototype<\/strong> for vehicle emission measurement in a multilane road. <strong>Project funded by MINECO, IPT-310000-2010-031<\/strong><\/p>\n\n\n\n<p>the goal of Project INNPACTO \u201c<strong>Development of a multilane detection system of Fuel Consumption and Vehicle Emissions<\/strong>\u201d, was to establish a Comprehensive Traffic Management System for impact monitoring of critical areas: environment, energy efficiency (fuel consumption) and traffic safety. LIR-Infrared LAB participation laid in applied its expertise in pollutant gas detection for the <strong>development of a prototype<\/strong> for measuring vehicles emissions on transit.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"238\" height=\"63\" src=\"https:\/\/storage.googleapis.com\/wp-uploads.bucket.wp.uc3m.es\/wp-content\/uploads\/sites\/90\/2023\/06\/06113249\/NNPACTO_02.jpg\" alt=\"\" class=\"wp-image-1379\"\/><\/figure>\n\n\n\n<p class=\"has-text-align-center\"><strong>IPT-31000-2010-031<\/strong><\/p>\n\n\n\n<p>This project goals:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>To develop a multilane traffic management system<\/strong> based on empirical data collection on real time (intensity, weather conditions, emissions and consumptions associated to a license plate).<\/li>\n\n\n\n<li><strong>To know which vehicles emit more pollutants<\/strong> (gross emitters) and <strong>to establish concrete policy measures<\/strong> based on their identification.<\/li>\n\n\n\n<li><strong>To reduce traffic emissions<\/strong> (CO2, CO, NOx, HC, PM) and <strong>upgrade energy efficiency<\/strong> (savings in emissions always lead to lower consumptions).<\/li>\n<\/ul>\n\n\n\n<p>This prototype is based on an <strong>infrared camera equipped with a filter holder<\/strong>, properly designed for gas concentration measurement. This system lies on the gas specific infrared firm that allows long distance detection. In particular, this system has been validated for CO2 and CO measurement.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"183\" src=\"https:\/\/storage.googleapis.com\/wp-uploads.bucket.wp.uc3m.es\/wp-content\/uploads\/sites\/90\/2023\/06\/06113250\/NNPACTO_03.gif\" alt=\"\" class=\"wp-image-1380\"\/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>INNPACTO: Multi-Lane System for the Detection of Emissions from Circulating Traffic In the frame of this project, LIR Infrared LAB-UC3M has applied its expertise in gas detection in the development of a prototype for vehicle emission measurement in a multilane road. Project funded by MINECO, IPT-310000-2010-031 the goal of Project INNPACTO \u201cDevelopment of a multilane [&hellip;]<\/p>\n","protected":false},"author":247,"featured_media":1495,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[43],"tags":[],"class_list":["post-1571","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-projects"],"_links":{"self":[{"href":"https:\/\/lir.uc3m.es\/en\/wp-json\/wp\/v2\/posts\/1571","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lir.uc3m.es\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lir.uc3m.es\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lir.uc3m.es\/en\/wp-json\/wp\/v2\/users\/247"}],"replies":[{"embeddable":true,"href":"https:\/\/lir.uc3m.es\/en\/wp-json\/wp\/v2\/comments?post=1571"}],"version-history":[{"count":2,"href":"https:\/\/lir.uc3m.es\/en\/wp-json\/wp\/v2\/posts\/1571\/revisions"}],"predecessor-version":[{"id":1575,"href":"https:\/\/lir.uc3m.es\/en\/wp-json\/wp\/v2\/posts\/1571\/revisions\/1575"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lir.uc3m.es\/en\/wp-json\/wp\/v2\/media\/1495"}],"wp:attachment":[{"href":"https:\/\/lir.uc3m.es\/en\/wp-json\/wp\/v2\/media?parent=1571"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lir.uc3m.es\/en\/wp-json\/wp\/v2\/categories?post=1571"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lir.uc3m.es\/en\/wp-json\/wp\/v2\/tags?post=1571"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}